Top Page > Main Chapters > Troubleshooting > Service Call 202-270 > SC200 (Engine: Image Writing)
SC No. |
Type |
Error Name/Error Condition/Major Cause/Solution |
SC202-00 |
D |
Polygon Motor Error |
After Polygon motor is stabilized, the ready signal is at the H level for 20 seconds consecutively. |
Polygon motor defective
IOB defective
|
Polygon motor defective
Confirm that the connector between laser unit and IOB is firmly connected. If necessary, connect the connector all the way in.
If the connector is broken, shorted, or grounded, replace the connector.
Replace the laser unit.
IOB defective
Update the engine software to the latest version.
Replace the IOB.
|
SC No. |
Type |
Error Name/Error Condition/Major Cause/Solution |
SC220-00 |
D |
Leading Edge: LD synchronization detection error |
The leading edge LD synchronization detection signal was not output within the specified time (sec.) while the polygon mirror motor was operating at normal speed. Error detection timing; During the startup operation of the machine or during printing. |
Laser unit defective (Synchronization optical system defective, LDB defective, LD defective)
BiCU defective (Image writing ASIC defective)
IOB defective
LDB – IOB, IOB – BiCU harness broken, or connector disconnected
|
Turn the main power OFF/ON.
Check for condensation on the mirrors and lenses.
Reconnect the connectors between LDB and IOB, and between IOB and BiCU.
Replace the laser unit.
Replace the BiCU.
Replace the harness between LDB and IOB, and between IOB and BiCU.
Replace the IOB.
|
SC No. |
Type |
Error Name/Error Condition/Major Cause/Solution |
SC270-00 |
D |
GAVD Communication Error |
The communication is not performed normally between CPU and image writing ASIC. Error detection timing; Only when initial setting is executed. |
|
Turn the main power OFF/ON.
Replace the BiCU.
|