SC100 (Engine: Scanning) (MP 501/601 Only)

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC101-01

D

Lamp Error (Scanning)



The white level peak did not reach the prescribed threshold when the white guide plate was scanned.

Error detection timing;

  • During a scan from the exposure glass:

    When the scanning of white guide plate is completed. (when the SHGH is negated)

  • During a scan from ARDF:

    During the shading operation.

    When the scanning of white guide plate is completed. (when the SHGH is negated)



  • Condensation in scanner unit

  • Connector disconnected

  • Scanner Carriage defective

  • BiCU defective

  • Harness defective

  • White Guide Plate dirty or defective

  • IOB defective



Check if the SC occurs by turning the main power OFF then ON. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power after each step.

  1. Reconnect the connector.

    Reconnect the following connectors;

    • Scanner Carriage – BiCU connector

    • BiCU – IOB connector

  2. Check the white guide plate (exposure glass).

    Check the white guide plate attached to the exposure glass. If the white guide plate is in an unusual state, replace the white guide plate.

  3. Scanner carriage defective

    Replace the scanner carriage.

  4. BiCU defective

    Replace the BiCU.

  5. Harness defective

    Replace the following harnesses.

    • Scanner Carriage – BiCU harness

    • BiCU – IOB harness

  6. IOB defective

    Replace the IOB.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC101-02

D

Lamp Error (Detecting the lighting error)



The white level peak did not reach the prescribed threshold when the white guide plate was scanned.

Error detection timing; During the scanner adjustment (detecting the lighting error) at the time of applying power source for scanner (when the main power is turned ON).



  • Condensation in scanner unit

  • Connector disconnected

  • Scanner Carriage defective

  • BiCU defective

  • Harness defective

  • White Guide Plate dirty or attachment fault

  • IOB defective



Check if the SC occurs by turning the main power OFF then ON. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power after each step.

  1. Reconnect the connector.

    Reconnect the following connectors;

    • Scanner Carriage – BiCU connector

    • SBU – LEDB connector (SBU side connector on the scanner carriage)

    • BiCU – IOB harness

  2. Check the white guide plate (exposure glass).

    Check the white guide plate attached to the exposure glass. If the white guide plate is in an unusual state, replace the white guide plate.

  3. Scanner carriage defective

    Replace the scanner carriage.

  4. BiCU defective

    Replace the BiCU.

  5. Harness defective

    Replace the following harnesses.

    • Scanner Carriage – BiCU harness

    • BiCU – IOB harness

  6. IOB defective

    Replace the IOB.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC102-00

D

LED Light Quantity Error



The white level peak exceeded the prescribed threshold when the white guide plate was scanned.

Error detection timing; During the scanner adjustment (detecting the lighting error) at the time of applying power source for scanner (when the main power is turned ON).



  • Connector disconnected

  • Scanner Carriage defective

  • BiCU defective

  • Harness defective

  • IOB defective



Check if the SC occurs by turning the main power OFF then ON. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power after each step.

  1. Reconnect the connector.

    Reconnect the following connectors;

    • Scanner Carriage – BiCU connector

    • SBU – LEDB connector (SBU side connector on the scanner carriage)

    • BiCU – IOB harness

  2. Check the white guide plate (exposure glass).

    Check the white guide plate attached to the exposure glass. If the white guide plate is in an unusual state, replace the white guide plate.

  3. Scanner carriage defective

    Replace the scanner carriage.

  4. BiCU defective

    Replace the BiCU.

  5. Harness defective

    Replace the following harnesses.

    • Scanner Carriage – BiCU harness

    • BiCU – IOB harness

  6. IOB defective

    Replace the IOB.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC120-00

D

Scanner Home Position error



The home position is not correct when the main power is turned ON, at the end of a reading process from the exposure glass and ARDF.



  • Scanner motor defective

  • Scanner HP sensor defective

  • SBU defective

  • BiCU defective

  • Controller board defective



  • Scanner motor defective

    1. Move the scanner carriage by hand to check whether it is unusually difficult to move.

    2. Check that the scanner driving belt is not disengaged.

    3. Reconnect the following connector.

      Scanner Motor – Controller Board connector

    4. If the connector is broken, shorted, or grounded, replace the connector.

    5. Replace the scanner motor.



  • Scanner HP sensor defective

    1. Check that the scanner HP sensor is correctly positioned.

    2. Reconnect the following connectors.

      • Scanner HP Sensor – SBU connector

      • SBU – Controller Board connector

    3. Replace the scanner HP sensor.

  • SBU defective

    Replace the scanner unit.

  • BiCU defective

    Replace the BiCU.

  • Controller board defective

    Replace the controller board.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC141-00

D

Black level detection error

The black level cannot be adjusted to the target level at the time of applying power source for scanner (when the main power is turned ON).

  • Scanner Carriage defective

  • BiCU defective

  • Harness defective

  • IOB defective



Check if the SC occurs by turning the power OFF then ON. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power after each step.

  1. Reconnect the following connectors.

    • Scanner Carriage – BiCU connector

    • BiCU – IOB connector

  2. Scanner carriage defective

    Replace the scanner carriage.

  3. BiCU defective

    Replace the BiCU.

  4. Harness defective

    Replace the following harnesses.

    • Scanner Carriage – BiCU harness

    • BiCU – IOB harness

  5. IOB defective

    Replace the IOB.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC142-00

D

White level detection error

The white level cannot be adjusted to the target level during auto gain control.

  • Condensation in scanner unit

  • Scanner Carriage defective

  • BiCU defective

  • Harness defective

  • Connector disconnected

  • White Guide Plate dirty or attachment fault



Check if the SC occurs by turning the power OFF then ON. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power after each step.

  1. Reconnect the following connectors.

    • Scanner Carriage – BiCU connector

    • SBU – LEDB connector (SBU side connector which is on the scanner carriage)

    • BiCU – IOB connector

  2. Check the white guide plate (exposure glass).

    Check the white guide plate attached to the exposure glass. If the white guide plate is in an unusual state, replace the white guide plate.

  3. Scanner carriage defective

    Replace the scanner carriage.

  4. BiCU defective

    Replace the BiCU.

  5. Harness defective

    Replace the following harnesses.

    • Scanner Carriage – BiCU harness

    • BiCU – IOB harness

  6. IOB defective

    Replace the IOB.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC144-00

D

SBU Communication Error



  • The machine cannot detect that the Scanner Carriage is connected.

  • The machine cannot communicate with the Scanner Carriage, or the communication data is incorrect.

  • The configuration of FPGA is not completed.

    Error detection timing: At the time of applying power source for scanner (when the main power is turned ON or when the machine returns from energy save mode)



  • Scanner Carriage defective

  • BiCU defective

  • IOB defective

  • Harness defective



Check if the SC occurs by turning the power OFF then ON. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power after each step.

  1. Reconnect the following connectors.

    • Scanner Carriage – BiCU connector

    • BiCU – IOB connector

  2. Scanner carriage defective

    Replace the scanner carriage.

  3. BiCU defective

    Replace the BiCU.

  4. IOB defective

    Replace the IOB.

  5. Harness defective

    Replace the following harnesses.

    • Scanner Carriage – BiCU harness

    • BiCU – IOB harness