SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC632-00 |
B |
Counter device error 1 |
After 3 attempts to send a data frame to the optional counter device via the serial communication line, no ACK signal was received within 100 ms. |
||
Serial line between the optional counter device, the relay board and copier control board is disconnected or damaged. |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC633-00 |
B |
Counter device error 2 |
After communication was established, the controller received the brake signal from the accounting device. |
||
Serial line between the optional counter device, the relay board and copier control board is disconnected or damaged. |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC634-00 |
B |
Counter device error 3 |
A backup RAM error was returned by the counter device. |
||
Counter device control board or the backup battery of counter device defective |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC635-00 |
B |
Counter device error 4 |
A backup battery error was returned by the counter device. |
||
Counter device control board or the backup battery of counter device defective |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC636-01 |
D |
IC Card Error (Expanded authentication module error) |
Issued when expanded authentication management is set to "ON" but either of the following occur.
|
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC636-02 |
D |
IC Card Error (Version error) |
The version of the expanded authentication module is not correct. |
||
Incorrect module version |
||
Install the correct file of the expanded authentication module. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC636-11 |
D |
IC Card Error (OSM user code file error) |
|
||
|
||
Use the user code configuration tool for OSM users (Idissuer.exe) to create the "usercode" and store it in the root folder of the SD card containing the IC card module (eccm.mod). |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC637-01 |
D |
Tracking Information Notification Error (Tracking application error) |
Tracking information was lost. |
||
|
||
Turn the main power off/on. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC637-02 |
D |
Tracking Information Notification Error (Management server error) |
Tracking information was lost. |
||
Communication with tracking management server failed.
|
||
Turn the main power off/on. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC641-00 |
D |
Communication error between BCU and Controller board. |
Controller board does not respond after BCU tries to communicate three times. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC650-01 |
B |
Remote Service Modem Communication Error (Dialup authentication failure) |
|
||
Dialup authentication failure |
||
Check the following SPs.
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC650-04 |
B |
Remote Service Modem Communication Error (dialup failing because of incorrect modem configuration) |
|
||
Dialup failing because of incorrect modem configuration |
||
Check if the setting of SP5-816-160 is correct. If it is correct, then there is a software bug. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC650-05 |
B |
Remote Service Modem Communication Error (insufficient current or connection fault) |
|
||
Insufficient current or connection fault |
||
The line is not supported and nothing can be done. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC650-13 |
B |
Remote Service Modem Communication Error (RC Gate Type M was installed but modem is not present (detected during operation)) |
|
||
RC Gate Type M was installed but modem is not present (detected during operation) |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC650-14 |
B |
Remote Service Modem Communication Error (RC Gate Type N was installed but modem is present or wired/wireless LAN is not working correctly) |
|
||
RC Gate Type N was installed but modem is present or wired/wireless LAN is not working correctly |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC651-01 |
C |
Illegal Remote Service Dial-up (Chat program parameter error) |
An unexpected error occurred when RC Gate Type M dialed up the NRS Center. |
||
Software bug |
||
Logging only. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC651-02 |
C |
Illegal Remote Service Dial-up (Chat program execution error) |
An unexpected error occurred when RC Gate dialed up the NRS Center. |
||
Software bug |
||
Logging only. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC652-00 |
D |
Remote service ID2 mismatching |
There was an authentication mismatch between ID2 for @Remote, the controller board, and NVRAM. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC653-00 |
D |
Incorrect remote service ID2 |
ID2 stored in the NVRAM has either of the following problems.
|
||
Replace the NVRAM. |
||
Clear the RC Gate installs status, write the common certificate, and then begin installation again. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC670-00 |
D |
Engine start up error |
|
||
|
||
Check the connection between the engine board and the controller board.
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC672-10 |
D |
Controller start up error |
After the machine was powered on, communication between the controller and the operation panel was not established. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC672-11 |
D |
Controller start up error |
After the machine was powered on, communication between the controller and the operation panel was not established, or communication with controller was interrupted after a normal startup. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC672-12 |
D |
Controller start up error |
Communication with controller was interrupted after a normal startup. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC672-13 |
D |
Controller start up error |
The operation panel detected that the controller is down. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC672-99 |
D |
Controller start up error |
The operation panel software ended abnormally. |
||
|
||
|