SC600 (Controller)

SC No.

Type

Details (Symptom, Possible Cause, Troubleshooting Procedures)

SC641-00

D

Communication error between BiCU and Controller board.

Controller board does not respond after BiCU tries to communicate three times.

  • Controller board software error

  • Connect error between BiCU and Controller board

  • BiCU software error

  • Check connections between Controller board and BiCU.

  • Turn the main power OFF then ON.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC670-01

D

Engine does not start up during the staring up

  • /ENGRDY signal was not asserted when the machine was turned on.

  • PCI I/F is not linked up when the machine returns from energy saver mode.

  • EC/PC/SC response was not received within specified time from power on.

  • Writing to Rapi driver failed (the other party not found through PCI).

  • Connection defect between controller board and BiCU.

  • BiCU is down / unstable

Engine board does not start up.

Refer to SC670 (engine start up error) is displayed.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC670-02

D

Engine does not start up after the staring up

  • CPU reset by software

  • CPU reset by anomaly CPU

  • CPU reset by hardware defect / noise

  • Hardware defect

Engine board reset unexpectedly.

Refer to SC670 (engine start up error) is displayed.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC672-10

D

Controller start up error

After the machine was powered on, communication between the controller and the operation panel was not established.

  • Controller stalled

  • Board installed incorrectly

  • Controller board defective

  • Operation panel connector loose, broken, or defective

  • Controller late

  1. Turn the main power OFF/ON.

  2. Check the connection of the operation panel.

  3. Check the connection of the controller board.

  4. Replace the controller board.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC672-11

D

Controller start up error

After the machine was powered on, communication between the controller and the operation panel was not established, or communication with controller was interrupted after a normal startup.

  • Controller stalled

  • Board installed incorrectly

  • Controller board defective

  • Operation panel connector loose, broken, or defective

  • Controller late

  1. Turn the main power OFF/ON.

  2. Check the connection of the operation panel.

  3. Check the connection of the controller board.

  4. Replace the controller board.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC672-12

D

Controller start up error

Communication with controller was interrupted after a normal startup.

  • Controller stalled

  • Board installed incorrectly

  • Controller board defective

  • Operation panel connector loose, broken, or defective

  • Controller late

  1. Turn the main power OFF/ON.

  2. Check the connection of the operation panel.

  3. Check the connection of the controller board.

  4. Replace the controller board.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC672-13

D

Controller start up error

The operation panel detects that the controller is down due to other reason shown in SC672-10, SC672-11, and SC672-12.

  • Controller stalled

  • Board installed incorrectly

  • Controller board defective

  • Operation panel connector loose, broken, or defective

  • Controller late

  1. Turn the main power OFF/ON.

  2. Check the connection of the operation panel.

  3. Check the connection of the controller board.

  4. Replace the controller board.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC672-99

D

Controller start up error

The operation panel software ended abnormally.

  • Controller stalled

  • Board installed incorrectly

  • Controller board defective

  • Operation panel connector loose, broken, or defective

  • Controller late

  1. Turn the main power OFF/ON.

  2. Check the connection of the operation panel.

  3. Check the connection of the controller board.

  4. Replace the controller board.