“Chart B” is greater effective for the improvement and it is also the permanent measure. However, productivity is decreased. Use either “Chart A” or “Chart B” depending on a customer’s demand.
Chart A
Chart B
If [Fusr Blt Smthng: Ppr Typ/Wt Coef] (No.102/103) is set to “100”, the belt smoothing interval function becomes shorter (See table below as A4/LT LEF.)
Interval |
Value |
Interval |
Value |
---|---|---|---|
10000 sheets |
1 |
333 sheets |
30 |
5000 sheets |
2 |
250 sheets |
40 |
3333 sheets |
3 |
200 sheets |
50 |
2500 sheets |
4 |
167 sheets |
60 |
2000 sheets |
5 |
143 sheets |
70 |
1667 sheets |
6 |
125 sheets |
80 |
1429 sheets |
7 |
111 sheets |
90 |
1250 sheets |
8 |
100 sheets |
100 |
1111 sheets |
9 |
67 sheets |
150 |
1000 sheets |
10 (default value) |
50 sheets |
200 |
500 sheets |
20 |
40 sheets |
255 |
After taking the above measures, do the color calibration adjustment of the external controller.