Skip header
 

Solution

1Set the setting of SP2-109-003 (Test Pattern) to “12 (Independent Pattern 2 dot)”.

2Print the test pattern.

3Is there uneven density between the left and right of the image?

Yes: Go to next step.

No: Finish

4Does the problem occur periodically at 40 mm interval?

Yes: Go to next step.

No: Refer to other troubleshooting.

5Execute “Process Control (SP3-011-001)”.

  • Normally, Process Control is executed at a first print just after turning on the machine. However, the adjustment of the AC charge bias may not be completed at once if the machine is located in the low temperature and low humidity condition. Therefore, execute the process control again manually.

6Print the target image.

7Is the printed image acceptable?

Yes: Finish

No: Go to next step.

8Increase the room temperature (guideline: 20°C or higher) and wait for 30 minutes at least.

  • Increasing the room temperature can restrain the increase of the charge roller resistance, and then solve the insufficient charge for the drum.

9Print the target image.

10Is the printed image acceptable?

Yes: Finish

No: Go to next step.

11Turn on the anti-condensation heater.

  • Turning on the anti-condensation heater can maintain adequate temperature inside the machine even if the main power of the machine is turned off.

12Print the target image.

13Is the printed image acceptable?

Yes: Finish

No: Go to next step.

14Replace the charger unit.

  • If the problem cannot be solved by steps 5 to 7 above and if immediate response is necessary, replace the charger unit.