Check the counter of PM parts around the drum (photoconductor unit), and then replace parts for which the counter has been exceeded.
In “Adjustment Settings for Skilled Operators”, execute “0502: [Execute Process Initial Setting]” (SP3-020-001).
Print the target image.
Is the printed image acceptable?
Yes: Finish
No: Go to next step
Execute [All Colors] in “0515: [Execute Developer Refreshing]” (SP3-062-001).
Print the target image.
Is the printed image acceptable?
Yes: Finish
No: Go to next step
Check the interval (pitch) of the uneven density.
Prepare a monochrome halftone image, and then print it for each color.
Use the NICE to find a problem unit.
Take measures according to the table below.
Pitch (Problem Unit) |
Measures |
---|---|
40 mm (Charge Roller) |
|
50 mm, 25 mm (Development Roller) |
|
63 mm (Paper Transfer Roller) |
Also, Refer to Uneven density: 63 mm Interval |
189 mm (Drum) |
Also, Refer to Uneven Density: 189 mm Interval (1) |
After taking the above measures, do the color calibration adjustment of the external controller.