Skip header
 

Solution

Chart 1

w_d194z0710.png

Table 1

Change all of the 5 setting items shown below.

No.

Custom Paper Settings

Details of Change

1

090 [Adj Fsng Tmp to Trnsf Ppr:Ppr: Qual]

092 [Adj Fsng Tmp to Trnsf Ppr:Ppr: Qual: S]

Change the setting to “1”.

2

093 [Adjust Adding Fusing Temperature 1]

094 [Adjst Addng Fusng Tempratre 1: Special]

Change the setting to “0”.

3

095 [Adjust Adding Fusing Temperature 2]

096 [Adjst Addng Fusng Tempratre 2: Special]

Change the setting to “15” if “Process Speed Setting (127/128)” is [High] or [Middle].

Change the setting to “5” if “Process Speed

Setting (127/128)” is [Low].

4

131 [Rdc. Init. CPM: Low Tmp. Envir.: Prod].

132 [Rdc. Init. CPM: Low Tmp. Envir.: Qual.]

Change the setting to “Level 3”.

5

133 [Rdc. In. CPM: N./H. Temp. Envr.: Prod.]

134 [Rdc. In. CPM: N./H. Temp. Envr.: Qual.]

Change the setting to “Level 3”.

Chart A

w_d194z0715.jpg

Flowchart for Decreasing Set Temperature

w_d194z0716.jpg

*1: Guidelines for Fusing Quality

Note

  • After taking the above measures, do the color calibration adjustment of the external controller.

Note