Cause

Double feed detection function is disabled when light adjustment returns failed due to the dirt of the double-feed sensor 1 (LED) and double-feed sensor 2 (Receptor); however it does not display and not notify to the users. (Logging SC591-00)

Solution

Set SP1-310-001(Dbl-Feed Detect Function: Disabled Display (0:Off 1:On)) to “1:On”.

If you set SP1-310-001 to “1:On”, the double feed detection disabled and contacting the supervisor message would display.

Note

  • Even if the light adjustment is succeeded under “in use” condition, the message remains on the screen. Rebooting the machine clears the message.