Skip header
 

Solution

This solution is only for CE.

Solution for Cause 1

  1. Check the PM counter of the parts around the drum (photoconductor unit) and then replace the parts for which the counter has been exceeded.

  2. Set SP1-131-001(Continues Print Mode Switch: Feed Permit Condition) to 1 (Productivity Mode).

    Note

    • Setting SP1-131-001 to “1 (Productivity Mode)” stops temperature adjustment even when the type/thickness of paper changes, thus completely eliminating wait time.

    • However, this also results in fusing temperature which does not match the paper. Therefore, uneven surface texture, offset, blisters (white spots), uneven gloss waves, residual gloss (gloss ghost), and fusing belt jam might occur.

Solution for Cause 2

  1. Check the PM counter of the parts around the drum (photoconductor unit) and then replace the parts for which the counter has been exceeded.

  2. Set SP3-600-070(Select ProCon: IMSSe Select) to 0 (OFF).

    Note

    • Setting SP3-600-070 to “0 (OFF)” stops changing the deposit amount even when the type/thickness of paper changes, thus completely eliminating wait time.

    • However, this also results in deposit amount which does not match the paper. Therefore, there is the possibility of slight changes in image density.

Note

  • After taking the above measures, we recommend performing color calibration again for the external controller.