Top Page > SC Codes > Service Call 700-740 > SC700 (Engine: Peripherals) > Cover Interposer Tray
Cover Interposer Tray
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC740-01 |
D |
Downstream device communication error |
Communication with the downstream device has established, but the device is not responding to the command sent out, even after being sent three times.
The port level of the downstream device does not become H level (break cancel) within specified time.
|
|
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC740-10 |
B |
1st Lift Motor Error |
The lift motor rotates in the ascending direction but the upper limit sensor does not detect within specified time (t0sec). (The first time: jam display, the second time: SC)
The lift motor rotates in the descending direction but the lower limit sensor does not detect within specified time (t0sec). (The first time: jam display, the second time: SC)
|
Lift motor defective/Connecter disconnected
Upper limit sensor defective/Connecter disconnected
Lower limit sensor defective/Connecter disconnected
Harness broken
PCB defective
Mechanical defect of the tray lift mechanism
|
Replace or reconnect the lift motor.
Replace or reconnect the upper limit sensor.
Replace or reconnect the lower limit sensor.
Replace the harness.
Replace the PCB.
Repair the tray lift mechanism
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC740-11 |
B |
1st Pick-Up Motor Error |
Home position is not detected within a specified number of pulses after the pick-up motor is driven. (The first time: jam display, the second time: SC)
Home position is still detected after the pick-up motor has been driven for a specified number of pulses. (The first time: jam display, the second time: SC)
|
|
Replace or reconnect the pick-up motor.
Replace or reconnect the home position sensor.
Replace the harness.
Replace the PCB.
Repair the pick-up mechanism
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC740-20 |
B |
2nd Lift Motor Error |
The lift motor rotates in the ascending direction but the upper limit sensor does not detect within specified time (t0sec). (The first time: jam display, the second time: SC)
The lift motor rotates in the descending direction but the lower limit sensor does not detect within specified time (t0sec). (The first time: jam display, the second time: SC)
|
|
Replace or reconnect the lift motor.
Replace or reconnect the upper limit sensor.
Replace or reconnect the lower limit sensor.
Replace the harness.
Replace the PCB.
Repair the tray lift mechanism
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC740-21 |
B |
2nd Pick-Up Motor Error |
Home position is not detected within a specified number of pulses after the pick-up motor is driven. (The first time: jam display, the second time: SC)
Home position is still detected after the pick-up motor has been driven for a specified number of pulses. (The first time: jam display, the second time: SC)
|
|
Replace or reconnect the pick-up motor.
Replace or reconnect the home position sensor.
Replace the harness.
Replace the PCB.
Repair the pick-up mechanism
|