SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC202-01 |
D |
Polygon Motor: ON Timeout Error: Bk |
SC202-03 |
D |
Polygon Motor: ON Timeout Error: Ma |
SC202-05 |
D |
Polygon Motor: ON Timeout Error: S |
After the polygon motor turned on, or within 15 sec. after the rpm’s changed, the motor did not enter READY status. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC203-00 |
D |
Polygon Motor: OFF Timeout Error: Bk |
SC203-03 |
D |
Polygon Motor: OFF Timeout Error: Ma |
SC203-05 |
D |
Polygon Motor: OFF Timeout Error: S |
The XSCRDY signal (polygon ready) never becomes inactive (H) after the polygon motor went OFF. Detail: If error is not detected, XSCRDY signal (polygon ready) becomes inactive (H) within 3 seconds. Detection is done in 450ms continuation (50ms x 10 times) |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC204-00 |
D |
Polygon Motor: XSCRDY Signal Error: Bk |
SC204-03 |
D |
Polygon Motor: XSCRDY Signal Error: Ma |
SC204-05 |
D |
Polygon Motor: XSCRDY Signal Error: S |
Inactive (H) occurred at least once after the polygon motor was rotated normally. Detail: In order to reduce false detection of inactive (H) due to noise or the like and detect the state of the XSCRDY signal in a timely way, if inactive (H) is detected for 9.2ms or longer (equal/greater than previous model), it is judged an error. SC detection operates via polling at intervals of 50ms. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC210-01 |
C |
Trailing Edge Beam Error: Bk |
SC210-02 |
C |
Trailing Edge Beam Error: Cy |
SC210-03 |
C |
Trailing Edge Beam Error: Ma |
SC210-04 |
C |
Trailing Edge Beam Error: Ye |
SC210-05 |
C |
Trailing Edge Beam Error: S |
During measurement of main magnification of the given color, the trailing edge beam detection signal was not detected, or the magnification could not be detected, or the detect magnification ended up outside the specified range. Details: These are detected only during measurement of main magnification. Once 6ms elapses after the start of measurement, it checks the measured value and issues SC if either 1 of the errors occur, a trailing edge beam error flag or a measurement completion flag. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC220-01 |
D |
Leading Edge: LD1 synchronization detection error: Bk |
SC220-02 |
D |
Leading Edge: LD1 synchronization detection error: Cy |
SC220-03 |
D |
Leading Edge: LD1 synchronization detection error: Ma |
SC220-04 |
D |
Leading Edge: LD1 synchronization detection error: Ye |
SC220-05 |
D |
Leading Edge: LD1 synchronization detection error: S |
The leading edge LD1 synchronization detection signal of the corresponding color was not output within 100 ms while the polygon mirror motor was operating at normal speed. Details:
|
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC230-01 |
D |
FGATE ON error: Bk |
SC230-02 |
D |
FGATE ON error: Cy |
SC230-03 |
D |
FGATE ON error: Ma |
SC230-04 |
D |
FGATE ON error: Ye |
SC230-05 |
D |
FGATE ON error: S |
The FGATE signal did not turn ON even if the specified period passed after the writing process of the corresponding color started. Details: After the specified period passed from the start of printing (STTRIG signal ON), it checks for the FGATE signal of the corresponding color to be ON. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC231-01 |
D |
FGATE OFF error: Bk |
SC231-02 |
D |
FGATE OFF error: Cy |
SC231-03 |
D |
FGATE OFF error: Ma |
SC231-04 |
D |
FGATE OFF error: Ye |
SC231-05 |
D |
FGATE OFF error: S |
The FGATE signal did not turn OFF even if the specified period passed after the writing process of the corresponding color ended. The FGATE signal did not turn OFF when the next job of the corresponding color started. Details:
|
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC240-01 |
D |
LD error: Bk |
SC240-02 |
D |
LD error: Cy |
SC240-03 |
D |
LD error: Ma |
SC240-04 |
D |
LD error: Ye |
SC240-05 |
D |
LD error: S |
LD currents exceeded the rated value after LD lighting Details: If the LD current exceeds 1.4 times the factory default, or exceeds the settable value, then it issues SC. To prevent false detection due to noise, it becomes an error if it exceeds the value twice in a row. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC260-01 |
C |
Laser Thermistor Error: Bk |
SC260-03 |
C |
Laser Thermistor Error: Ma |
SC260-05 |
C |
Laser Thermistor Error: S |
Details: The machine detects this SC when the machine turns on and recovers from energy saver mode. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC265-02 |
C |
Skew correction error: Cy |
SC265-03 |
C |
Skew correction error: Ma |
SC265-04 |
C |
Skew correction error: Ye |
SC265-05 |
C |
Skew correction error: S |
The skew control pulse total (SP2-104-007 to 010) is not within range. Detail When MUSIC executed, if the accumulated skew pulse qty. exceeds ±50 pulses, it issues SC. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC270-01 |
D |
LD ASIC communication error: Bk |
SC270-02 |
D |
LD ASIC communication error: Cy |
SC270-03 |
D |
LD ASIC communication error: Ma |
SC270-04 |
D |
LD ASIC communication error: Ye |
SC270-05 |
D |
LD ASIC communication error: S |
SC270-10 |
D |
LD ASIC communication error: Others |
On startup: Written to and read the same register but the values were different. VTEC: Monitored the parity and retried three times. Details:
|
||
SC270-01 to 05
|
||
SC270-01 to 05
SC270-10
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC274-01 |
D |
Image transfer error: Bk |
SC274-02 |
D |
Image transfer error: Cy |
SC274-03 |
D |
Image transfer error: Ma |
SC274-04 |
D |
Image transfer error: Ye |
SC274-05 |
D |
Image transfer error: S |
A fatal error occurred with the image-related data received by the LDB of the corresponding color. Details:
|
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC276-01 |
D |
Microcomputer communication error: Bk |
SC276-02 |
D |
Microcomputer communication error: Cy |
SC276-03 |
D |
Microcomputer communication error: Ma |
SC276-04 |
D |
Microcomputer communication error: Ye |
SC276-05 |
D |
Microcomputer communication error: S |
The LDB (microcomputer) of the corresponding color is not working normally. Details: The microcomputer toggles the port output for input to write control ASIC and the write control ASIC monitors whether this signal is toggled within the time allowed. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC285-00 |
D |
MUSIC error |
The results of MUSIC pattern reading failed 4 times while the machine is turned ON. (SC496 occurred 4 times in a row) |
||
|
||
|