Skip header
 

SC2xx: Polygon Motor Errors

Code

Level

Details

202

D

Polygon Motor On Timeout Error

No lock signal was received within 10 sec. after the polygon motor was turned on.

  • The polygon motor driver I/F harness is loose, broken, or defective.

  • The polygon motor is broken or defective.

  • Cycle the power OFF/ON.

  • Replace the I/F harness.

  • Replace the polygon motor.

  • Replace the laser unit.

Code

Level

Details

203

D

Polygon Motor Off Timeout Error

The lock signal did not go inactive within 20 sec. after the polygon motor was turned off.

  • The polygon motor I/F harness is loose, broken, or defective.

  • The motor driver board is defective.

  • The motor is defective.

  • Cycle the power OFF/ON.

  • Replace the I/F harness.

  • Replace the polygon motor.

  • Replace the laser unit.

Code

Level

Details

204

D

Polygon Motor Lock Signal Error

Four samplings within 200 ms indicate that the polygon motor lock signal remained inactive beyond the prescribed number of revolutions.

  • The I/F harness between the motor and driver board is loose, broken, or defective.

  • The driver board is defective.

  • The motor is defective.

  • Cycle the power OFF/ON.

  • Replace the I/F harness.

  • Replace the polygon motor.

  • Replace the laser unit.

Code

Level

Details

220

D

Beam Synchronization Error

The top cover is closed and locked, and the polygon motor is locked, but laser synchronization could not be achieved within 400 ms.

  • The I/F harness of the LDB is loose, broken, or defective.

  • The polygon motor is locked.

  • The angle of incidence of the laser beam and photo-detector is not correct.

  • Cycle the power OFF/ON.

  • Replace the I/F harness.

  • Replace the polygon motor.

  • Replace the laser unit.

  • Replace the main board.