Keep EEPROM away from any objects that can cause static electricity. Static electricity can damage EEPROM data.
Make sure that you have the SMC report (factory settings). This report comes with the machine.
Print out the SMC data (SP5-990-001).
Turn the main power switch off.
Install an SD card into SD card slot 2. Then turn the main power on.
Copy the EEPROM data to an SD card (SP5-824-001) onto the SD card.
Turn off the main power switch. Then unplug the power cord.
Replace the EEPROM on the BCU and reassemble the machine.
Plug in the power cord. Then turn the main power switch on.
When you do this, SC995 will be displayed. However, DO NOT turn off the main power switch. Continue with this procedure.
Enter the machine serial number (SP-811-001).
For information on how to configure SP5-811-001, contact your supervisor or support center.
Set the machine state destination (SP-996-001).
For information on how to configure SP5-996-001, contact your supervisor or support center.
Turn the main power switch off and on.
If the BCU serial number is not entered correctly, SC995-01 (serial number entry error) appears.
Execute SP5-825-001 to download the EEPROM data in the SD onto the new EEPROM.
Turn off the main power switch.
Remove the SD card from SD card slot 2.
Turn the main power switch on.
In accordance with SMC data, specify the UP and SP mode settings.