Skip header
 

Paper Exit Unit

1Upper Cover (Upper Cover)

2Fusing Unit (Fusing Unit)

3Junction gate solenoid (Junction Gate Solenoid)

4Release the connector to remove the harness guide [A] (_screw.png×1, _connector.png×2).

m187z4236.jpg

5Remove the belt and screw at the right side of the paper exit unit [A] (_screw.png×1, _timing_belt.png×1).

m187z4237.jpg

6Remove the screw at the rear side of the paper exit unit [A] (_screw.png×1).

m187z4232.jpg

7Release the connector in the back of the paper exit unit [A] to remove the paper exit unit [A] (_connector.png×1).

m187z4238.jpg